Specifications 121
Power supply specifications
Depending on the installed options and/or the regional location where the server was purchased, the
server is configured with one of the following power supplies:
HPE 550 W Power Supply
HPE 800 W / 900 W Gold AC Power Input Module
This is supported when the two-bay HPE RPS Backplane is installed. The module wattage rating
changes depending on whether one or two power input modules are installed in the server:
o One power input module installed (non-redundant): 900 W
o Two power input modules installed (redundant): 800 W
HPE 900 W AC 240VDC Power Input Module
This is supported when the two-bay HPE 900 W AC 240VDC RPS Power Backplane option is
installed.
o The 240 V DC function of this module is intended for server installations based in China.
These are Entry Level Power Supply products for ProLiant servers. For more information about the power
supply features, specifications, and compatibility, see the Hewlett Packard Enterprise website
(http://www.hpe.com/servers/powersupplies).
CAUTION: Check the system and power supply input ratings before powering up the server.
Hot-plug power supply calculations
For hot-plug power supply specifications and calculators to determine electrical and heat loading for the
server, see the Hewlett Packard Enterprise Power Advisor website
(http://www.hpe.com/info/poweradvisor/online).