The StoreOnce 5200, StoreOnce 5250, and StoreOnce 5650 Systems will have external SAS cables.
If the StoreOnce 3640 System has capacity upgrades installed, it will have external SAS cables.
3. If you are installing a card in slots 1 or 2, remove the primary PCIe riser cage. If you are installing a
card in slots 4 or 5, remove the secondary PCIe riser cage.
4. The following example illustrates the removal process. There may already be cards installed.
5. Make a note of the internal cable connections before you disconnect them.
You must reconnect the cables correctly for the system to work.
6. Disconnect the cables from the storage controller card and expander cards, as necessary.
7. Remove the blanking plate for the appropriate slot.
8. The following example illustrates where the first 10 GbE card is being installed in slot 1. The SAS
expander card occupies slot 3.
1
2
3
9. Install the PCIe card.
Installing optional hardware 137