Figure 6-7 Connecting unshielded network cables
Step 3 Connect the unshielded network cables to a cable management strip.
NOTE
The following describes connection of one unshielded network cable. Connect all the unshielded
network cables in the same way.
1. Use a pair of diagonal pliers to strip off about 15 cm of insulation coating of the
unshielded network cable.
2. Divide the four twisted pairs of the cable into eight wires and arrange them orderly.
3. At the local device side, put each two wires through a pair of wire dividers at the left side
of the cable management strip and lead the wires into the wire slots at the left side. At
the remote device side, put each two wires through a pair of wire dividers at the right
side of the cable management strip and lead the wires into the wire slots at the right side.
See Figure 6-8
Huawei
AR100&AR120&AR150&AR160&AR200&AR1200&AR
1600&AR2200&AR3200&AR3600 series Enterprise
Routers
Hardware Installation and Maintenance Guide
6 Installing the AR1200 Series/AR2204/AR2220E/
AR2220/AR2204E Series Routers
Issue 05 (2018-07-30) Huawei Proprietary and Confidential
Copyright © Huawei Technologies Co., Ltd.
82