BYPASS OP9000
Performance and Features 3 Working Principle and Functions
Document Version
T2-0416xx-20050330-C-1.20
(March 2005)
HUAWEI TECHNOLOGIES CO.,
LTD.
- 3-7 -
Specifications
Table 3-2 Specifications of DCP
Front panel
RUN
TO11 TO12 RI11 RI12 RO1 TI1
RI11 RI21
RI12 RI22
TO21 TO22 RI21 RI22 RO2 TI2
DCP
Specifications
Dimensions:
Board (PCB):169.8 mm (length) x 130 mm (width) x 1.6 mm (thickness)
Front panel:141.5 mm (length) x 19.6 mm (width)
Indicators on the front panel:
Silkscreen Color Function
RUN Green / Red / Off Green – Means Normal or no alarm;
Red – Means Alarm Occurs;
Off – Means out of Power;
R11 Green / Red / Off Green – Means traffic is on channel 1A;
Red – Means signal loss on channel 1A;
Off – Means no loss of signal while traffic is on channel 1B or
out of power;
R12 Green / Red / Off Green – Means traffic is on channel 1B;
Red – Means signal loss on channel 1B;
Off Means no loss of signal while traffic is on channel 1A or
out of power;
R21 Green / Red / Off Green – Means traffic is on channel 2A;
Red – Means signal loss on channel 2A;
Off – Means no loss of signal while traffic is on channel 2B or
out of power;
R22 Green / Red / Off Green – Means traffic is on channel 2B;
Red – Means signal loss on channel 2B;
Off Means no loss of signal while traffic is on channel 2A or
out of power;