Right-click T-CONT Info. in the navigation tree and choose ADD T-
CONT from the shortcut menu. In the dialog box that is displayed, set the
parameters.
T-CONT Index: 1
DBA Profile: FTTx
Right-click T-CONT1 in the navigation tree and choose Add GEM Port
from the shortcut menu. In the dialog box that is displayed, set the parameters.
GEM Port Index: 1
Priority Queue: 1