EasyManua.ls Logo

Huawei FusionServer Pro 2298 V5 - Operating Temperature Limitations; RAS Features

Huawei FusionServer Pro 2298 V5
82 pages
Print Icon
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
Callout No. Description
4 Year and month (two characters).
The rst character indicates the year.
Digits 1 to 9 indicate years 2001 to 2009, respectively.
Letters A to H indicate years 2010 to 2017, respectively.
Letters J to N indicate years 2018 to 2022, respectively.
Letters P to Y indicate years 2023 to 2032, respectively.
NOTE
The years from 2010 are represented by uppercase letters excluding
I, O, and Z because the three letters are similar to digits 1, 0, and 2.
The second character indicates the month.
Digits 1 to 9 indicate January to September, respectively.
Letters A to C indicate October to December, respectively.
5 Sequence number (six characters).
6 RoHS compliance (one character). Y indicates RoHS compliant.
7 Internal model, that is, product name.
A.2 Operating Temperature Limitations
Table A-2 Operating temperature limitations
Conguration
Max. 30°C (86°F) Max. 35°C (95°F)
24 x 3.5" drive
conguration
All options supported All options supported
A.3 RAS Features
The server supports a variety of Reliability, Availability, and Serviceability (RAS)
features. You can congure these features for better RAS.
For details about how to congure RAS features, see Huawei Server Purley
Platform BIOS Parameter Reference.
Table A-3 RAS features
Module
Feature Description
CPU Corrected Machine Check
Interrupt
Corrects error-triggered interruption.
DIMM Failed DIMM Isolation Identies a faulty DIMM and isolates it
from others before it is replaced.
Huawei FusionServer Pro 2298 V5 Server
Technical White Paper A Appendix
Issue 05 (2020-09-03) Copyright © Huawei Technologies Co., Ltd. 60