Activity
Indicator
(Green)
Fault Indicator
(Yellow)
Description
Steady on O The NVMe drive is working properly.
Blinking at 2 Hz O Data is being read from or written
to the NVMe drive.
O Blinking at 2 Hz The NVMe drive is being located or
hot-swapped.
O Blinking at 0.5
Hz
The hot removal process is
complete, and the NVMe drive is
removable.
Steady on/O Steady on The NVMe drive is faulty.
5.5.4 RAID Controller Card
The RAID controller card supports RAID conguration, RAID level migration, and
drive roaming.
● If SAS/SATA drives are used as rear drives, a RAID controller card can be
congured to manage the rear drives.
● Contact your local Huawei sales representative or use the Computing
Product Compatibility Checker to determine the components to be used.
● For details about the RAID controller card, see Huawei V5 Server RAID
Controller Card User Guide.
5.6 Network
5.6.1 LOMs
LOMs provide network expansion capabilities.
Table 5-13 LOMs supported by the 2298 V5
NIC Type
Chip
Model
Port
Type
Number
of Ports
NC-SI WOL PXE
LOM X722 10GE
optical
port
2 √ √ √
GE
electrical
port
2 √ √ √
Huawei FusionServer Pro 2298 V5 Server
Technical White Paper 5 Hardware Description
Issue 05 (2020-09-03) Copyright © Huawei Technologies Co., Ltd. 31