EasyManua.ls Logo

Huawei LUNA2000 - Battery Storage and Recharge

Huawei LUNA2000
96 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
Check Item Check Method Maintenance
Inter
val
System
running status
Check that the battery is not
damaged or deformed.
Check that the battery does not
generate abnormal sound when it is
in operation.
Check that the battery parameters
are correctly set when the battery is
running.
Once every 6
months
Electrical
Connection
Check that cables are secured.
Check that cables are intact, and
that in particular, the parts touching
the metallic surface are not
scratched.
Check that unused DC input
terminals, battery terminals, and
COM ports are locked by watertight
caps.
The rst inspection is
6 months after the
initial
commissioning.
From then on, the
interval can be 6 to
12 months.
Grounding
reliability
Check that ground cables are securely
connected.
The rst inspection is
6 months after the
initial
commissioning.
From then on, the
interval can be 6 to
12 months.
7.3
Troubleshooting
Alarm severities are dened as follows:
Major: The battery shuts down or some functions are abnormal due to a fault.
Minor: Some components of the battery are faulty but the battery can still
work.
LUNA2000-(5-30)-S0
User Manual 7 System Maintenance
Issue 01 (2020-10-20) Copyright © Huawei Technologies Co., Ltd. 74

Table of Contents