NO TICE
During DC input power cabling, leave at least 150 mm of slack. The axial tension
on PV connectors must not exceed 80 N. Radial stress or torque must not be
generated on PV connectors.
Figure 5-19 DC input power cabling requirement
----End
5.8 Installing the Communications Cable
Precautions
When routing communications cables, separate communications cables from
power cables to prevent communication from being aected.
SUN2000-(175KTL-H0, 185KTL-INH0, 185KTL-H1)
User Manual 5 Electrical Connections
Issue 19 (2023-12-20) Copyright © Huawei Technologies Co., Ltd. 59