7 LCD
Huawei Proprietary and Confidential
Copyright © Huawei Technologies Co., Ltd.
LCD
Operation Procedure
5. On the Comm. Param. page, press .
6. Set Address, Protocol, Baud Rate, and
Match Resistance, and press .
The selectable display addresses include 1
to 63.
The selectable display protocol is Modbus.
The selectable display baud rates include
4800bps, 9600bps, and 19200bps.
The selectable display status of the match
resistance include Disconnect and
Connect.
This parameter is set to Disconnect by
default. If signals are distorted or the
communication is of poor quality because
the signal cable is too long, set the
parameter to Connect.
----End
7.2.9 Setting Protection Parameters
This topic describes how to set SUN2000 protection parameters on the monitoring panel.
Procedure
The following table describes the procedure for setting protection parameters. The
parameter values in the figures are for reference only.