EasyManua.ls Logo

Huawei SUN2000-50KTL-JPM0 - Page 51

Huawei SUN2000-50KTL-JPM0
113 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
SUN2000-(50KTL-JPM0, 50KTL-JPM1, 63KTL-JPM0)
User Manual
5 Electrical Connections
Copyright © Huawei Technologies Co., Ltd.
45
Figure 5-16 Measuring voltage
If the voltage is a negative value, the PV string is of reversed polarity. Correct before
connecting this string to the SUN2000.
If the voltage is greater than 1100 V, too many PV modules are configured to the same
string. Remove some PV modules.
Step 3 Pull out the blue dustproof plugs from the ends of the DC input connectors.
Before performing Step 4, ensure that the two DC switches are OFF.
Step 4 Insert the positive and negative connectors into the corresponding positive and negative DC
input terminals of the SUN2000 until they snap into place.
After the positive and negative connectors snap into place, pull test to the DC input power
cable is recommended.