Loading...
Item SUN2000-115KT
L-M2
SUN2000-110KT
L-M2
SUN2000-100KT
L-M2
SUN2000-100KT
L-INM2
Rated input
voltage
600 V (400 V)
and 720 V (480
V)
600 V (380 V/400
V)
570 V (380 V),
600 V (400 V)
and 720 V (480
V)
620 V (415 V)
and 720 V (480
V)
Maximum short-
circuit current
(per MPPT)
40 A
Maximum
backfeed current
to the PV array
0 A
Number of inputs 20
Number of MPP
trackers
10
Note a: The maximum input voltage is the upper threshold of the DC voltage. If the input voltage
exceeds the threshold, the solar inverter may be damaged.
Note b: If the input voltage is beyond the operating voltage range, the solar inverter cannot work
properly.
Output
Item
SUN2000-115KT
L-M2
SUN2000-110KT
L-M2
SUN2000-100KT
L-M2
SUN2000-100KT
L-INM2
Rated active
power
115 kW 110 kW 100 kW 100 kW
Maximum
apparent power
125 kVA 121 kVA 110 kVA 110 kVA
Maximum active
power (cosφ = 1)
125 kW 121 kW 110 kW 110 kW
Rated output
voltage
a
(phase
voltage/line
voltage)
230 V/400 V and
277 V/480 V,
3 W + (N)
b
+ PE
220 V/380 V and
230 V/400 V,
3 W + (N)
b
+ PE
220 V/380 V, 230
V/400 V and 277
V/480 V,
3 W + (N)
b
+ PE
240 V/415 V and
277 V/480 V,
3 W + (N)
b
+ PE
Rated output
current
166.0 A (400 V)
and 138.4 A (480
V)
167.2 A (380 V)
and 158.8 A (400
V)
152.0 A (380 V),
144.4 A (400 V)
and 120.3 A (480
V)
139.2 A (415 V),
120.3 A (480 V)
Rated grid
frequency
50 Hz/60 Hz
SUN2000-(100KTL, 110KTL, 115KTL)-M2