Communicating 
(Communicating means that 
communication with the 
management system is in 
progress. However, if a 
mobile phone accesses the 
SUN2000, the LED indicates 
the "mobile phone access 
status: blinking green at long 
intervals" first.) 
 
----End 
6.3 Powering Off the System 
Context 
 
 
 
After the SUN2000 powers off, the remaining electricity and heat may still cause electric 
shock and burns. After power-off, wait 5 minutes before servicing the SUN2000. Always 
wear protective gloves when servicing the SUN2000 
 
If the SUN2000 is connected to the battery, ensure that a shutdown command is sent from 
the app. Power off the system after the SUN2000 has shut down. If no shutdown command 
is sent from the app, the SUN2000 will shut down after the power grid is powered off. The 
SUN2000 will wait for 1 minute and restart (not grid-tied) and charge the battery, which 
poses an electrical hazard when you turn off the DC switch. 
 
If Off-grid mode is set to Enable and Grid-tied/Off-grid mode switching is set to 
Automatic switching for the SUN2000, ensure that a shutdown command is sent from the 
app and power off the system only after the SUN2000 has shut down. If no shutdown 
command is sent from the app, the SUN2000 will switch to the backup state after the 
power grid is powered off, which poses an electrical hazard when you turn off the DC 
switch. 
Procedure 
Step 1  Send a shutdown command from the app. Perform operations by referring to 7.4.3.5 Starting 
or Shutting Down the SUN2000 if you log in as installer; perform operations by referring to 
7.5.6 Settings if you log in as user.