DIMENSIONS
ACC1200,ACC99D Cabinet :
12⅜" H x 15" W x 6
716
" D
(31.37 cm H x 39.37 cm W x 16.38 cm D)
ACCPED Metal Pedestal:
36⅛" H x 15" W x 5" D
(91.45 cm H x 39.37 cm W x 12.7 cm D)
ACC1200PP, ACC99D-PP Plastic Pedestal:
38⅜" H x 21
916
" W x 15⅞" D
(97.47 cm H x 54.61 cm W x 40.32 cm D)
ELECTRICAL
Transformer Input
Supply wires must be 14 AWG (1.85 mm) or larger!
120/230 VAC
50/60 Hz
1.2 A max at 120V/0.73 A max at 230V
Transformer output
24 VAC, 4A, @ 120 VAC
Station output: 0.56 A @ 24 VAC
Pump/Master Valve output: 325 mA @24 VAC
24 VAC Test terminal output: 420 mA @ 24 VAC
Solenoid capacity: 2 standard 24 VAC Hunter solenoids per output (0.56 Amps max), 14 solenoids max simultaneous
(includes dual P/MV outputs).
Battery, facepack: 9 VDC alkaline, for facepack remote power only.
Battery, facepack, internal: CR2032 lithium for real time clock only.
Cleaning
Clean only with cloth dampened with mild soapy water.
FEATURES & GENERAL SPECIFICATIONS
• 6 Automatic Programs
• 10 Start Times per program
• Station Run Times, 1 second to 6 hours in Conventional Controllers, and 15 seconds to 6 hours in Decoder Controllers
• Delay between Stations, 1 second to 9 hours, 59 minutes
• Interval Day scheduling, 1 to 31 days
• 4 Custom Manual programs (for manual or remote start only)
• 20 Simultaneous Station Groups with up to 4 stations each
• 2 normally closed Pump/Master Valve outputs, configured by station
• 1 Flow Meter, with Station level learning and diagnostics
• 4 Hunter “Clik” sensor inputs, with programmable shutdown by program
• Test Program run times: Conventional, 1 second to 15 minutes each, Decoder, 15 seconds to 15 minutes each
• Up to 42 stations, conventional
• Up to 99 stations, decoder