ContaminationSensor CS1000 CS1220 VIMS Features
HYDAC Filter Systems GmbH
en
Page 15 / 36
CS1000 CAT-VIMS3478916 en 2009-04-15.doc 2009-04-15
CS1220 VIMS Features
The CS1220 VIMS ContaminationSensor is a stationary measurement unit for the
continuous monitoring of solid particle contamination in hydraulic and lubrication
systems.
The CS is designed to be used in low- or high-pressure hydraulic and lubrication
circuits and test benches where a small amount of oil (between 30 ml/min and 300
ml/min) is diverted for measurement purposes.
The ContaminationSensor is approved for a maximum operating pressure up to 300
bar (4350 psi) and viscosity of up to 1000 mm²/s.
The particulate contamination is recorded by an optical measurement cell.
The sensor has the following features:
4 analog output voltage outputs 0 – 5 V each, 3 for ISO-code and 1 for status
results are output as a cleanliness code according to:
ISO 4406:1999
flange installation
The display and the buttons are without function in this model.
CS1000 Restrictions on use
NOTICE
Prohibited operating fluids
The CS will be destroyed.
Operate the CS1000 only in conjunction with the permitted operating fluids.
CS 1xx0 is suitable for operation with petroleum or petroleum-based
refinates.
Observe the maximum operating pressure on the CS 1000 type label.

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Hydac ContaminationSensor CS1220 VIMS and is the answer not in the manual?

Hydac ContaminationSensor CS1220 VIMS Specifications

General IconGeneral
BrandHydac
ModelContaminationSensor CS1220 VIMS
CategoryAccessories
LanguageEnglish

Related product manuals