ContaminationSensor CS1000 Analog Output
HYDAC Filter Systems GmbH
en
Page 26 / 36
CS1000 CAT-VIMS3478916 en 2009-04-15.doc 2009-04-15
Status Signal (PIN 8)
The voltage of the status output signal is dependent on the status of the CS1000 as
shown in the table below:
Status Voltage U
CS is functioning correctly U = 1.25 V
Device error / CS not ready U = 1.50 V
Flow insufficient (Flow 2 low) U = 1.75 V
ISO <9.<8.<7 U = 2.00 V
No measured value
(flow not defined)
U = 2.25 V