EasyManuals Logo

Hypertherm HyPrecision 50S User Manual

Hypertherm HyPrecision 50S
202 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Page #141 background imageLoading...
Page #141 background image
HyPrecision 50S/60S/75S Operator Manual 808690 141
5 Preventive maintenance
Preventive maintenance
1. Put high-pressure antiseize lubricant on the threads of the outlet adapter.
2. Use 2 wrenches to tighten the outlet adapter into the 3/8-inch gland nut.
3. Put high-pressure antiseize lubricant on the outside threads of the high-pressure water fitting.
4. Use 2 wrenches to tighten the high-pressure water fitting in the valve body.
5. Replace the hydraulic fitting SAE O-ring on the hydraulic hose fitting.
Put O-ring lubricant on the O-ring.
6. Use 2 wrenches to tighten the hydraulic hose fitting in the O-ring boss adapter.

Table of Contents

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Hypertherm HyPrecision 50S and is the answer not in the manual?

Hypertherm HyPrecision 50S Specifications

General IconGeneral
BrandHypertherm
ModelHyPrecision 50S
CategoryWater Pump
LanguageEnglish

Related product manuals