94 HyPrecision 50S/60S/75S Operator Manual 808690
5 Preventive maintenance
Preventive maintenance
Test the low-pressure water TDS level
Some TDS meters require calibration before use. For best results, calibrate the meter at 25.0°C (77°F). Refer to
the instructions supplied with the TDS meter.
If multiple readings are taken, turn the meter OFF between readings.
Required parts, tools, and materials
13897 TDS meter
Container for a water sample
Clean, deionized water or filtered water
Do this task when the pump is running in cooling mode.
1. Open the water valve to drain the water from the system. Make sure that the water pressure gauges
show0.0bar or0kPa(0psi).
2. Let the water run for 30 seconds.
3. Take a sample from the wastewater outlet. If the wastewater outlet is not accessible, take a sample of the
supply water going into the pump.
Service Interval
Test the low-pressure water TDS level After every 1,000 hours of operation
2
3
1
1 Water valve in the open position 2 Prefilter water pressure
3 Postfilter water pressure
3
1
2
1 COOLING IN
2 CUTTING WATER IN
3 WASTEWATER OUT

Table of Contents

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Hypertherm HyPrecision 50S and is the answer not in the manual?

Hypertherm HyPrecision 50S Specifications

General IconGeneral
BrandHypertherm
ModelHyPrecision 50S
CategoryWater Pump
LanguageEnglish

Related product manuals