9 Installation
Installation
Do the first startup
Use this procedure at installation and after maintenance or repairs are done on the intensifier, the high-pressure
water system, or the low-pressure water system.
Do a preoperation inspection
Examine the equipment before starting the pump.
Look for leaks, deterioration, damage, or other conditions that can interfere with operation.
Look at the sight gauge on the hydraulic fluid tank. If necessary, add hydraulic fluid.
Close all doors and replace all covers, including access covers.
WARNING
Do not leave waterjet cutting equipment turned on and unattended.
CAUTION
Air-cooled systems must be connected to the external air cooler before starting the motor. Failure to
connect the COOLING IN and COOLING OUT lines can damage the hydraulic hoses, the
hydraulic filter, or the air cooler.
CAUTION
If a water line, fitting, or valve might be frozen, do not operate the pump. Thaw the equipment until
water moves freely through the entire water circuit.
High-pressure water can cause eye injuries. Wear approved eye protection when operating or
working near this equipment.
This waterjet equipment might exceed national and local codes for permitted noise levels.
When this pump is running, the noise level is 75 dB(A) to 80 dB(A). Noise level is related to factors
such as water flow rate, pipe layout, and the acoustical characteristics of the building.
Prolonged exposure to noise can cause permanent hearing loss. Wear approved ear protection and
control exposure time when operating or working near this equipment.
High-pressure water can cause severe cuts or lacerations, abrasions, and punctures. Wear
approved hand protection when operating or working near this equipment.
CAUTION
Make sure that all connections are tight before operating this equipment.

Table of Contents

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Hypertherm HyPrecision 50S and is the answer not in the manual?

Hypertherm HyPrecision 50S Specifications

General IconGeneral
BrandHypertherm
ModelHyPrecision 50S
CategoryWater Pump
LanguageEnglish

Related product manuals