9 – Installation
Installation
Required parts, tools, and materials
pH tester
Silica test kit
Water hardness (calcium carbonate) test kit
13897 TDS meter
Container for water sample
1. Collect a sample of water. Make sure that the water is clear, odorless, and free of biological materials.
2. Test the pH. The ideal pH measurement is between 6.0 and 8.0.
3. Test the silica (SiO
2
) content. The silica content must be less than 0.0015% (15 parts per million [ppm]).
4. Test the water hardness. The result must be equal to or less than 0.006% (60 ppm).
5. Test the TDS concentration. The ideal range is 0.005% to 0.015% (50 ppm to 150 ppm).
A TDS level that is less than 0.005% (50 ppm) can harm waterjet parts and requires the use of
nonmetallic or stainless steel fittings.
Treat water with a TDS level that is more than 0.015% (150 ppm) with reverse osmosis or consider
using deionized water.
CAUTION
A TDS value of less than 0.0005% (5 ppm) can damage stainless steel parts.
% 0.002 0.004 0.006 0.008 0.01 0.012 .0014 0.016 0.018 0.02 0.022 0.024
ppm20406080100120140160180200220240
Unacceptable
less than 0.005%
(50 ppm)
Ideal
0.005% to 0.015%
(50 ppm to 150 ppm)
Acceptable
0.015% to 0.022%
(150 ppm to 220 ppm)
Unacceptable
more than 0.022%
(220 ppm)
Use nonmetallic or
stainless steel
fittings.
—
Consider using a reverse
osmosis system to remove
TDS.
Use a reverse
osmosis system to
remove TDS.