Power SuPPly SetuP
Powermax105 Operator Manual 2-5
Install a line-disconnect switch
Use a line-disconnect switch for each power supply so that the operator can turn off the incoming power quickly in an
emergency. Locate the switch so that it is easily accessible to the operator. Installation must be performed by a licensed
electrician according to national and local codes. The interrupt level of the switch must equal or exceed the continuous
rating of the fuses. In addition, the switch should:
• Isolate the electrical equipment and disconnect all live conductors from the incoming supply voltage when in the
OFF position.
• Have one OFF and one ON position that are clearly marked with O (OFF) and I (ON).
• Have an external operating handle that can be locked in the OFF position.
• Contain a power-operated mechanism that serves as an emergency stop.
• Have appropriate slow-blow fuses installed. See page 2-6 Power connection for the Powermax105 for
recommended fuse sizes.
Requirements for grounding
To ensure personal safety, proper operation, and to reduce electromagnetic interference (EMI), the power supply must
be properly grounded.
• The power supply must be grounded through the power cord according to national and local electrical codes.
• Three-phase service must be of the 4-wire type with a green or green/yellow wire for protective earth ground
and must comply with national and local requirements.
• Refer to the separate Safety and Compliance Manual included with your system for more information on
grounding.

Table of Contents

Other manuals for Hypertherm Powermax105

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Hypertherm Powermax105 and is the answer not in the manual?

Hypertherm Powermax105 Specifications

General IconGeneral
BrandHypertherm
ModelPowermax105
CategoryWelding System
LanguageEnglish

Related product manuals