IBERITAL
INSTALLATION AND OPERATION MANUAL Page 55
ENGLISH
Crono Function
ENABLED/DISABLED
The display will show the ‘CRONO FUNCTION’ for each group; use the UP/DOWN buttons to ENABLED or DISABLE
the function.
The feed time will appear each time we make a co ee; if it is DISABLED the selected option will appear on the
display.
Once this procedure is completed, press the MENU button to move on to the following option:
Doses setting
ENABLED/DISABLED
The display will show the dose setting mode. If it is ENABLED, then the dose can be programmed for the various
options (1 espresso, 1 co ee, etc.); if it is DISABLED, the dose cannot be programmed and the dose entered prior
to this selection will remain.
Press the UP/DOWN buttons to ENABLE/DISABLE the dose setting mode.
Once this procedure is completed, press the MENU button to move on to the following option:
Continous key
ENABLED/DISABLED
The display will show the ‘CONTINUOS’ (NON-STOP) programming mode. The CONTINUOS dose will only function if
it is ENABLED.
Once this procedure is completed, press the MENU button to move on to the following option:
Mixed tea
with pump / without pump
The display will show the ‘MIXED TEA’ option, to select water for tea that is either hot water only ‘without pump’
option or hot water mixed with cold water ‘with pump’ option.
Once this procedure is completed, press the MENU button to move on to the following option:
Steam Boiler Gr.
O/1/2
* The ‘STEAM BOILER’ OPTION IS NOT AVAILABLE and will always leave the factory set at ‘O’ (NOT AVAILABLE).
Once this procedure is completed, press the MENU button to move on to the following option:
PreBrewing
ENABLED/DISABLED
The display will give the option of ENABLING or DISABLING the ‘PRE-BREW’ function using the UP/DOWN buttons.
ACTIVATING the ‘PRE-BREW’ function and pressing the MENU button, the display will show:
PreBrew. ON
1 espresso xxxx seg
The display will show the timer option for ‘PRE-BREW ON’ for each co ee selection (1 espresso, 1 co ee, etc.).
Pressing the UP/DOWN buttons, the desired time in seconds (from 0.1 sec. to 5 sec. in jumps of 0.1 sec.) can be
selected. Press the MENU button to select the ‘ON’ times for the rest of the selections.
Once this procedure is completed, press the MENU button to move on to the following option:
OPTION IS NOT AVAILABLE