Towers
212 AS/400e System Handbook
At least one of the HSL cables for the Model 820 must be either the #1460 or #1461. The
#1462 15m HSL cable can only be used on HSL port A1 of the Model 820 to directly connect
Migration Towers #5033, #5034, or #5035. The #1462 15m HSL cable can be used on all HSL
ports of the Models 830 and 840.
Select one of the following SPCN cables:
• #1463 - 2m SPCN cable
• #1464 - 6m SPCN cable
• #1465 - 15m SPCN cable
The #5075 is capable of controlling Ultra2 SCSI disk units, and a maximum of one disk unit
controller is allowed within a #5075.
On new orders, specify one line cord with each #5075 PCI Expansion Tower.
Note: Some countries offer fewer choices of line cords, and some countries are shipped a
default line cord type. Marketing configurators are to default to the line cord type of the
system, if the system unit line cord type is not the #1413.
The #5156 may be specified to add an additional 575-watt power supply for redundancy and
an additional cooling fan.
Marketing configurators default a #5156 for the #5075 on any Model 820 that contains a
#5155. The #5156 is not mandatory and can be removed.
When the #5075 is attached to the Model 270, the seven PCI IOAs are supported (driven) by
an embedded 32 MB PCI IOP and by feature #2842 PCI IOPs or feature #2890 Integrated
Netfinity Servers.
When the #5075 is attached to the Model 820, the seven PCI IOAs are supported (driven) by
an embedded 32 MB PCI IOP and by feature #2843 PCI IOPs or feature #2790 Integrated
Netfinity Servers.
#5075s are not allowed to migrate on Model 820 upgrades to Model 830.