v Follow the suggested actions in the order in which they are listed in the Action column until the problem is
solved.
v See Chapter 4, “Parts listing, Types 7871 and 1949,” on page 41 to determine which components are CRUs and
which components are FRUs.
v If an action step is preceded by “(Trained service technician only),” that step must be performed only by a
trained service technician.
Error Code Type Error Message Action
0x80010900 Error System board (Inlet Temp)
temperature over/under critical
threshold with chassis reading:
X, Threshold: Y
1. Make sure that the room temperature is within
the operating specifications (see “Features and
specifications” on page 8).
2. Make sure that none of the air vents on the
BladeCenter unit and on the blade server are
blocked.
3. Make sure that all of the fans on the BladeCenter
unit are running.
0x80010B00 Error System board (Inlet Temp)
temperature over/under
non-recoverable threshold.
Reading: X, Threshold: Y
1. Make sure that the room temperature is within
the operating specifications (see “Features and
specifications” on page 8).
2. Make sure that none of the air vents on the
BladeCenter unit and on the blade server are
blocked.
3. Make sure that all of the fans on the BladeCenter
unit are running.
0x80070100 Warning Memory device X, temperature
(DIMM X Temp) warning [Note:
X=1-18]
1. Make sure that the room temperature is within
the operating specifications (see “Features and
specifications” on page 8).
2. Make sure that none of the air vents on the
BladeCenter unit and on the blade server are
blocked.
3. Make sure that all of the fans on the BladeCenter
unit are running.
0x80070100 Warning Processor X, temperature (CPU
X OverTemp) warning [Note:
X=1-2]
1. Make sure that the room temperature is within
the operating specifications (see “Features and
specifications” on page 8).
2. Make sure that none of the air vents on the
BladeCenter unit and on the blade server are
blocked.
3. Make sure that all of the fans on the BladeCenter
unit are running.
0x80070200 Error Memory device X, temperature
(DIMM X Temp) critical [Note:
X=1-18]
1. Make sure that the room temperature is within
the operating specifications (see “Features and
specifications” on page 8).
2. Make sure that none of the air vents on the
BladeCenter unit and on the blade server are
blocked.
3. Make sure that all of the fans on the BladeCenter
unit are running.
106 BladeCenter HS22V Type 7871 and 1949: Problem Determination and Service Guide

Table of Contents

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the IBM BladeCenter HS22V 7871 and is the answer not in the manual?

IBM BladeCenter HS22V 7871 Specifications

General IconGeneral
BrandIBM
ModelBladeCenter HS22V 7871
CategoryServer
LanguageEnglish

Related product manuals