v Follow the suggested actions in the order in which they are listed in the Action column until the problem is
solved.
v See Chapter 4, “Parts listing, Types 7871 and 1949,” on page 41 to determine which components are CRUs and
which components are FRUs.
v If an action step is preceded by “(Trained service technician only),” that step must be performed only by a
trained service technician.
Error Code Type Error Message Action
0x800B0100 Error Memory device 0 (Bckup Mem
Status) is not redundant
1. Check the event logs for other memory errors that
might occur (see “Error logs” on page 99).
2. Reseat all of the memory modules in the blade
server (see “Removing a memory module” on
page 63 and “Installing a memory module” on
page 64).
3. Make sure all of the memory is enabled in the
Setup utility (see “Using the Setup utility” on
page 20). Notice which memory modules are
disabled before continuing to the next step.
4. If the error still occurs, replace the memory
modules that were disabled in the Setup utility
(see “Removing a memory module” on page 63
and “Installing a memory module” on page 64).
5. (Trained service technician only) If the error still
occurs, replace the microprocessor that controls
the failing memory module.
Note: DIMM sockets one through nine are
controlled by the first microprocessor and DIMM
sockets ten through eighteen are controlled by the
second microprocessor. See “Removing a
microprocessor and heat sink” on page 85 and
“Installing a microprocessor and heat sink” on
page 88.
0x800B0300 Warning Memory device 0 (Bckup Mem
Status) is not redundant and
operational with minimal
resources
1. Check the event logs for other memory errors that
might occur (see “Error logs” on page 99).
2. Reseat all of the memory modules in the blade
server (see “Removing a memory module” on
page 63 and “Installing a memory module” on
page 64).
3. Make sure all of the memory is enabled in the
Setup utility (see “Using the Setup utility” on
page 20). Notice which memory modules are
disabled before continuing to the next step.
4. If the error still occurs, replace the memory
modules that were disabled in the Setup utility
(see “Removing a memory module” on page 63
and “Installing a memory module” on page 64).
5. (Trained service technician only) If the error still
occurs, replace the microprocessor that controls
the failing memory module.
Note: DIMM sockets one through nine are
controlled by the first microprocessor and DIMM
sockets ten through eighteen are controlled by the
second microprocessor. See “Removing a
microprocessor and heat sink” on page 85 and
“Installing a microprocessor and heat sink” on
page 88.
110 BladeCenter HS22V Type 7871 and 1949: Problem Determination and Service Guide

Table of Contents

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the IBM BladeCenter HS22V 7871 and is the answer not in the manual?

IBM BladeCenter HS22V 7871 Specifications

General IconGeneral
BrandIBM
ModelBladeCenter HS22V 7871
CategoryServer
LanguageEnglish

Related product manuals