Serviceable: Yes
CIM Information: Prefix: PLAT and ID: 0530
SNMP Trap ID: 0
Automatically notify Support: No
User response: Complete the following steps until the problem is solved:
1. Check the Chassis Management Module or Flex System Manager event log for any fan- or cooling-related issues.
2. Make sure that the airflow at the front and rear of the chassis is not obstructed and that fillers are in place and
correctly installed.
3. Make sure that the room temperature is within operating specifications.
4. If there are no other thermal issues, replace the I/O expansion adapter.
80070601-2c02ffff Sensor Mezz Exp 2 temp has transitioned to non-recoverable.
Explanation: The temperature of the I/O expansion adapter in I/O expansion connector 2 has exceeded its specified
threshold. The compute node has attempted a soft shutdown.
May also be shown as 800706012c02ffff or 0x800706012c02ffff
Severity: Error
Alert Category: Critical - Temperature
Serviceable: Yes
CIM Information: Prefix: PLAT and ID: 0530
SNMP Trap ID: 0
Automatically notify Support: No
User response: Complete the following steps until the problem is solved:
1. Check the Chassis Management Module or Flex System Manager event log for any fan- or cooling-related issues.
2. Make sure that the airflow at the front and rear of the chassis is not obstructed and that fillers are in place and
correctly installed.
3. Make sure that the room temperature is within operating specifications.
4. If there are no other thermal issues, replace the I/O expansion adapter.
80070601-2c03ffff Sensor Mezz Exp 3 temp has transitioned to non-recoverable.
Explanation: The temperature of the I/O expansion adapter in I/O expansion connector 3 has exceeded its specified
threshold. The compute node has attempted a soft shutdown.
May also be shown as 800706012c03ffff or 0x800706012c03ffff
Severity: Error
Alert Category: Critical - Temperature
Serviceable: Yes
CIM Information: Prefix: PLAT and ID: 0530
SNMP Trap ID: 0
Automatically notify Support: No
User response: Complete the following steps until the problem is solved:
1. Check the Chassis Management Module or Flex System Manager event log for any fan- or cooling-related issues.
2. Make sure that the airflow at the front and rear of the chassis is not obstructed and that fillers are in place and
correctly installed.
3. Make sure that the room temperature is within operating specifications.
4. If there are no other thermal issues, replace the I/O expansion adapter.
80070601-2c02ffff • 80070601-2c03ffff