Automatically notify Support: Yes
User response:
1. Check http://www.ibm.com/supportportal/ for RETAIN tips or firmware updates that might correct the error.
2. Make sure that all I/O expansion adapters have correct and matching levels of device drivers and firmware.
3. Check the system-event log for additional information about failing components.
4. If there are no entries related to the error in the system-event log, contact IBM Support and send DSA data to
IBM.
806f0813-2584ffff A Uncorrectable Bus Error has occurred on system [ComputerSystemElementName].
Explanation: A catastrophic system error has occurred. The system firmware will attempt to analyze the failure to
determine whether the failure was due to a hardware component or a software component.
May also be shown as 806f08132584ffff or 0x806f08132584ffff
Severity: Error
Alert Category: Critical - Other
Serviceable: Yes
CIM Information: Prefix: PLAT and ID: 0240
SNMP Trap ID: 50
Automatically notify Support: Yes
User response:
1. Check http://www.ibm.com/supportportal/ for RETAIN tips or firmware updates that might correct the error.
2. Make sure that all I/O expansion adapters have correct and matching levels of device drivers and firmware.
3. Check the system-event log for additional information about failing components.
4. If there are no entries related to the error in the system-event log, contact IBM Support and send DSA data to
IBM.
806f0823-2101ffff Watchdog Timer interrupt occurred for [WatchdogElementName].
Explanation: The IPMI watchdog timer has expired. A watchdog interrupt has occurred.
May also be shown as 806f08232101ffff or 0x806f08232101ffff
Severity: Info
Alert Category: System - Other
Serviceable: No
CIM Information: Prefix: PLAT and ID: 0376
SNMP Trap ID:
Automatically notify Support: No
User response: Information only; no action is required.
806f090c-2001ffff [PhysicalMemoryElementName] on Subsystem [MemoryElementName] Throttled.
Explanation: This message is for the use case when an implementation has detected Memory has been Throttled.
May also be shown as 806f090c2001ffff or 0x806f090c2001ffff
Severity: Warning
Alert Category: System - Other
Serviceable: Yes
CIM Information: Prefix: PLAT and ID: 0142
806f0813-2584ffff • 806f090c-2001ffff
246
IBM Flex System x440 Compute Node Types 7917 and 2584: Installation and Service Guide