2. Remove CPU 1 and inspect the CPU socket for bent pins.
3. Swap CPU 1 and CPU 2. If the error goes away, replace the original CPU 1.
4. If the problem persists, System board may need to be replaced.(Trained service personnel only)
81010202-0701ffff Numeric sensor [NumericSensorElementName] going low (lower critical) has deasserted.
Explanation: This message is for the use case when an implementation has detected a Lower Critical sensor going
low has deasserted. A previously low voltage has returned to above its specified threshold (sensor Planar 12V, Planar
3.3V, or Planar 5V).
May also be shown as 810102020701ffff or 0x810102020701ffff
Severity: Info
Alert Category: Critical - Voltage
Serviceable: No
CIM Information: Prefix: PLAT and ID: 0481
SNMP Trap ID: 1
Automatically notify Support: No
User response: Information only; no action is required.
81010202-2801ffff Numeric sensor [NumericSensorElementName] going low (lower critical) has deasserted.
Explanation: The previously low CMOS battery voltage has returned to above its specified threshold.
May also be shown as 810102022801ffff or 0x810102022801ffff
Severity: Info
Alert Category: Critical - Voltage
Serviceable: No
CIM Information: Prefix: PLAT and ID: 0481
SNMP Trap ID: 1
Automatically notify Support: No
User response: Information only; no action is required.
81010902-0701ffff Numeric sensor [NumericSensorElementName] going high (upper critical) has deasserted.
Explanation: A previously high voltage has returned to below its specified threshold (sensor Planar 12V, Planar 3.3V,
or Planar 5V).
May also be shown as 810109020701ffff or 0x810109020701ffff
Severity: Info
Alert Category: Critical - Voltage
Serviceable: No
CIM Information: Prefix: PLAT and ID: 0495
SNMP Trap ID: 1
Automatically notify Support: No
User response: Information only; no action is required.