089-802-xxx
Explanation: Aborted due a system resource availability error.
User response: Complete the following steps:
1. Make sure at least 1 GB of memory is installed in the compute node (see “Installing a DIMM” on page 502).
2. Make sure that the DSA code is up-to-date, upgrade if necessary; then, run the test again. The latest code can be
found at http://www.ibm.com/support/entry/portal/docdisplay?lndocid=SERV-DSA.
3. Make sure that the system firmware level is up-to-date, upgrade if necessary; then, run the test again. The
installed firmware level can be found in the DSA log within the Firmware/VPD section for this component. The
latest level firmware for this component can be found at http://www.ibm.com/support/fixcentral/.
4. If the compute node has stopped responding, turn off and restart the compute node; then, run the test again. See
“Turning off the compute node” on page 15 and “Turning on the compute node” on page 13.
5. (Trained service technician only) If the component failure remains, see Chapter 7, “Installing, removing, and
replacing compute node components,” on page 487 to replace the failed component.
IMM2 self-tests
Use this information to diagnose and solve IMM2 self-test errors.
Follow the suggested actions in the order in which they are listed in the Action
column until the problem is solved. See Chapter 5, “Parts listing, Types 7917 and
2584,” on page 51 to determine which components are Tier 1 customer replaceable
units (CRUs) and which components are Tier 2 customer replaceable units (CRUs).
Ethernet device tests
Use this information to diagnose and solve Ethernet device errors.
Follow the suggested actions in the order in which they are listed in the Action
column until the problem is solved. See Chapter 5, “Parts listing, Types 7917 and
2584,” on page 51 to determine which components are Tier 1 customer replaceable
units (CRUs) and which components are Tier 2 customer replaceable units (CRUs).
Memory self-tests
Use this information to diagnose and solve memory self-test errors.
Follow the suggested actions in the order in which they are listed in the Action
column until the problem is solved. See Chapter 5, “Parts listing, Types 7917 and
2584,” on page 51 to determine which components are Tier 1 customer replaceable
units (CRUs) and which components are Tier 2 customer replaceable units (CRUs).
Optical drive self-tests
Use this information to diagnose and solve optical drive self-test errors.
Follow the suggested actions in the order in which they are listed in the Action
column until the problem is solved. See Chapter 5, “Parts listing, Types 7917 and
2584,” on page 51 to determine which components are Tier 1 customer replaceable
units (CRUs) and which components are Tier 2 customer replaceable units (CRUs).
Hard disk drive self-tests
Use this information to diagnose and resolve hard disk drive self-test errors.
Follow the suggested actions in the order in which they are listed in the Action
column until the problem is solved. See Chapter 5, “Parts listing, Types 7917 and
2584,” on page 51 to determine which components are Tier 1 customer replaceable
units (CRUs) and which components are Tier 2 customer replaceable units (CRUs).
089-802-xxx