Note: By default, only secure protocols, such as, SSH and HTTPS, are enabled.
2. Use a serial cable to connect to the I/O module to further isolate the problem.
Cannot communicate with the CMM
Use the information in this section to troubleshoot the compute node when you
cannot communicate with the CMM.
Action
Complete the following steps until the problem is solved:
1. Make sure that the protocols that you are using are enabled.
Note: By default, only secure protocols, such as, SSH and HTTPS, are enabled.
2. Use a serial cable to connect to the I/O module to further isolate the problem.
3. Reset the CMM to the default settings by pressing the reset button on the
CMM.
Cannot communicate with the I/O module
Use the information in this section to troubleshoot the compute node when you
cannot communicate with the I/O module.
Action
Complete the following steps until the problem is solved:
1. Make sure that the protocols that you are using are enabled.
Note: By default, only secure protocols, such as, SSH and HTTPS, are enabled.
2. Use a serial cable to connect to the I/O module to further isolate the problem.
One or more compute nodes are unable to communicate with
SAN
Use the information in this section to troubleshoot one or more compute nodes are
unable to communicate with SAN.
v Make sure that:
1. The I/O module is powered on and the appropriate ports are enabled on the
I/O module.
2. The CMM has reported that the I/O module has completed POST and that
no errors have been reported in the logs.
3. The SAN device is powered on and is functional.
4. All cables between the I/O module and the SAN device are properly
connected and secure and that the activity LEDs are lit on the applicable
ports.
v See the documentation for the I/O module for additional information about
troubleshooting SAN connectivity or network connectivity issues.
Complete the following steps until the problem is solved:
Cannot connect during initial setup
Use the information in this section to troubleshoot the compute node when you
cannot connect during initial setup.
One compute node is unable to connect during the initial setup:
460 IBM Flex System x440 Compute Node Types 7917 and 2584: Installation and Service Guide

Table of Contents

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the IBM Flex System x440 Compute Node and is the answer not in the manual?

IBM Flex System x440 Compute Node Specifications

General IconGeneral
BrandIBM
ModelFlex System x440 Compute Node
CategoryServer
LanguageEnglish

Related product manuals