v Follow the suggested actions in the order in which they are listed in the Action column until the problem is
solved.
v See Chapter 5, “Parts listing, Types 7917 and 2584,” on page 51 to determine which components are customer
replaceable units (CRU) and which components are field replaceable units (FRU) that must be replaced only
by a trained service technician.
v If an action step is preceded by “(Trained service technician only),” that step must be performed only by a
trained service technician.
Symptom Action
Compute node is unresponsive
(POST is complete and
operating system is running)
If you are in the same location as the compute node, complete the following steps:
1. If you are using a KVM connection, make sure that the connection is operating
correctly. Otherwise, make sure that the keyboard and mouse are operating
correctly.
2. If possible, log in to the compute node and verify that all applications are
running (no applications are hung).
3. Restart the compute node.
4. Make sure that any new software has been installed and configured correctly.
5. Contact your place of purchase of the software or your software provider.
If you are accessing the compute node from a remote location, complete the
following steps:
1. Make sure that all applications are running (no applications are hung).
2. Attempt to log out of the system and log back in.
3. Validate the network access by pinging or running a trace route to the
compute node from a command line:
a. If you are unable to get a response during a ping test, attempt to ping
another compute node in the chassis to determine whether it is a
connection problem or compute node problem.
b. Run a trace route to determine where the connection breaks down. Attempt
to resolve a connection issue with either the VPN or the point at which the
connection breaks down.
4. Restart the compute node remotely through the management interface.
5. If the problem remains, verify that any new software has been installed and
configured correctly.
6. Contact your place of purchase of the software or your software provider.
Unusual smell An unusual smell might be coming from newly installed equipment. If the
problem remains, contact IBM Support.
Compute node seems to be
running hot
Multiple compute nodes or chassis:
1. Make sure that the room temperature is within the specified range (see
“Features and specifications” on page 4).
2. Check the IBM Flex System Manager management software or CMM event log
for rising temperature events. If there are no events, the compute node is
running within normal operating temperatures. Note that you can expect some
variation in temperature.
Single compute node:
Check the IBM Flex System Manager management software or CMM event log for
rising temperature events. If there are no events, the compute node is running
within normal operating temperatures. Note that you can expect some variation in
temperature.
Cracked parts or cracked
chassis
Contact IBM Support.
480 IBM Flex System x440 Compute Node Types 7917 and 2584: Installation and Service Guide

Table of Contents

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the IBM Flex System x440 Compute Node and is the answer not in the manual?

IBM Flex System x440 Compute Node Specifications

General IconGeneral
BrandIBM
ModelFlex System x440 Compute Node
CategoryServer
LanguageEnglish

Related product manuals