The following illustration shows the LEDs and controls on the light path
diagnostics panel.
v Remind button: This button places the system-error LED on the front panel into
Remind mode. In Remind mode, the system-error LED flashes once every 2
seconds until the problem is corrected, the server is restarted, or a new problem
occurs.
By placing the system-error LED indicator in Remind mode, you acknowledge
that you are aware of the last failure but will not take immediate action to
correct the problem.
v NMI button: Press this button to force a nonmaskable interrupt to the
microprocessor. You might have to use a pen or the end of a straightened paper
clip to press the button. You can also use it to force a blue screen memory
dump. Use this button only when you are directed to do so by the IBM service
support.
v Checkpoint code display: This display provides a checkpoint code that indicates
the point at which the system stopped during the boot block and POST. A
checkpoint code is either a byte or a word value that is produced by UEFI. The
display does not provide error codes or suggest components to be replaced.
v Reset button: Press this button to reset the server and run the power-on self-test
(POST). You might have to use a pen or the end of a straightened paper clip to
press the button. The Reset button is in the lower-right corner of the light path
diagnostics panel.
20 System x3690 X5 Types 7147, 7148, 7149, and 7192: Installation and User's Guide