EasyManuals Logo

IBM x3200 M2 Type 4367 User Manual

IBM x3200 M2 Type 4367
266 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Page #141 background imageLoading...
Page #141 background image
v Follow the suggested actions in the order in which they are listed in the Action column until the problem
is solved.
v See Chapter 3, “Parts listing, System x3200 M2 Types 4367 and 4368,” on page 33 to determine which
components are customer replaceable units (CRU) and which components are field replaceable units
(FRU).
v If an action step is preceded by “(Trained service technician only),” that step must be performed only by a
trained service technician.
Beep code Description Action
1-2-4 RAM refresh verification failed.
1. Reseat the DIMMs.
2. Replace the following components one at a
time, in the order shown, restarting the
server each time:
a. DIMMs
b. (Trained service technician only) System
board
1-3-1 First 64 K RAM test failed.
1. Reseat the DIMMs.
2. Clear CMOS. See “System-board jumpers”
on page 13 for information about how to
clear CMOS.
3. Replace the following components one at a
time, in the order shown, restarting the
server each time:
a. DIMMs
b. (Trained service technician only) System
board
2-1-1 Secondary DMA register failed. (Trained service technician only) Replace the
system board.
2-1-2 Primary DMA register failed. (Trained service technician only) Replace the
system board.
2-1-3 Primary interrupt mask register failed. (Trained service technician only) Replace the
system board.
2-1-4 Secondary interrupt mask register failed. (Trained service technician only) Replace the
system board.
2-3-4 Search for video ROM failed. (Trained service technician only) Replace the
system board.
3-3-2 Critical SMBUS error occurred.
1. Disconnect the power cord, wait 30
seconds, and retry.
2. Reseat the following components:
a. DIMM
b. System board
3. Replace the following components one at a
time, in the order shown, restarting the
server each time:
a. DIMM
b. (Trained service technician only) System
board
Chapter 5. Diagnostics 123

Table of Contents

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the IBM x3200 M2 Type 4367 and is the answer not in the manual?

IBM x3200 M2 Type 4367 Specifications

General IconGeneral
ProcessorIntel Xeon 3000 Sequence, Intel Core 2 Duo, Intel Pentium Dual-Core
Memory Slots4 DIMM slots
ChipsetIntel 3200
Storage ControllerIntegrated SATA controller
Form FactorTower
MemoryUp to 8GB DDR2
StorageSATA
Hard Drive Bays4
RAID SupportRAID 0, 1
Network ControllerIntegrated Broadcom Gigabit Ethernet
Expansion Slots1 PCI-Express x8, 1 PCI-Express x1, 2 PCI
Power Supply400W fixed
Operating System SupportMicrosoft Windows Server, Red Hat Enterprise Linux, SUSE Linux Enterprise Server
Processor CoresDual-core, Quad-core (Xeon 3200 series)