Table 9. DSA diagnostic messages (continued)
v Follow the suggested actions in the order in which they are listed in the Action column until the problem is solved.
v See Chapter 3, “Parts listing, System x3200 M2 Types 4367 and 4368,” on page 33 to determine which components are
customer replaceable units (CRU) and which components are field replaceable units (FRU).
v If an action step is preceded by “(Trained service technician only),” that step must be performed only by a trained
service technician.
Message
number Component Test State Description Action
215-904-xxx Optical drive Self-Test Failed A read error
occurred.
1. Insert a new CD or DVD into the drive
and wait for 15 seconds for the media
to be recognized.
2. Run the test again.
3. Check the drive cabling for loose or
broken connections at both ends or
damage to the cable. Replace the cable
if it is damaged.
4. Run the test again.
5. For additional troubleshooting
information, see the “Troubleshooting
CD and DVD drive issues” site at
http://www.ibm.com/support/
docview.wss?uid=psg1MIGR-41559.
6. Run the test again.
7. Replace the optical drive.
8. Run the test again.
9. If the problem remains, collect the data
from the DSA event log and send it to
IBM Service. For information about
contacting and sending data to IBM
Service, see http://www.ibm.com/
support/docview.wss?uid=psg1SERV-
CALL.
217-000-000 Hard Drive Drive Self Test Pass The test passed. N/A
217-800-000 Hard Drive Drive Self Test Abort The test was
canceled.
N/A
217-900-000 Hard Drive Drive Self Test Failed The hard drive
self-test detected
a failure.
1. Check cable connections.
2. Rerun the test.
3. Verify the firmware is at the latest level.
Rerun the test. If the problem remains,
contact your IBM technical-support
representative.
Chapter 5. Diagnostics
211

Table of Contents

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the IBM x3200 M2 Type 4367 and is the answer not in the manual?

IBM x3200 M2 Type 4367 Specifications

General IconGeneral
ProcessorIntel Xeon 3000 Sequence, Intel Core 2 Duo, Intel Pentium Dual-Core
Memory Slots4 DIMM slots
ChipsetIntel 3200
Storage ControllerIntegrated SATA controller
Form FactorTower
MemoryUp to 8GB DDR2
StorageSATA
Hard Drive Bays4
RAID SupportRAID 0, 1
Network ControllerIntegrated Broadcom Gigabit Ethernet
Expansion Slots1 PCI-Express x8, 1 PCI-Express x1, 2 PCI
Power Supply400W fixed
Operating System SupportMicrosoft Windows Server, Red Hat Enterprise Linux, SUSE Linux Enterprise Server
Processor CoresDual-core, Quad-core (Xeon 3200 series)