v Follow the suggested actions in the order in which they are listed in the Action column until the problem
is solved.
v See Chapter 3, “Parts listing, System x3200 M2 Types 4367 and 4368,” on page 33 to determine which
components are customer replaceable units (CRU) and which components are field replaceable units
(FRU).
v If an action step is preceded by “(Trained service technician only),” that step must be performed only by a
trained service technician.
System-error log message Action
System is over recommended voltage for +3.3V
1. Reseat the following components:
a. Hot-swap power supplies, if any are installed
b. Power supply cables on the system board
2. (Trained service technician only) Replace the system board.
System is over recommended voltage for 1.5V
CPU
1. Reseat the following components:
a. Hot-swap power supplies, if any are installed
b. Power supply cables on the system board
2. (Trained service technician only) Replace the system board.
System is over recommended voltage on VRM (Trained service technician only) Reseat the microprocessor.
System is under recommended voltage for
+3.3V
1. Reseat the following components:
a. Hot-swap power supplies, if any are installed
b. Power supply cables on the system board
2. (Trained service technician only) Replace the system board.
System is under recommended voltage for 1.5V
CPU
1. Reseat the following components:
a. Hot-swap power supplies, if any are installed
b. Power supply cables on the system board
2. (Trained service technician only) Replace the system board.
System is under recommended voltage on VRM (Trained service technician only) Reseat the microprocessor.
System log 75% full Clear the current logs.
System log cleared Information only.
System Memory Error
1. Reseat the DIMMs.
2. Replace the DIMMs.
System over recommended voltage for +12V
1. Reseat the following components:
a. Hot-swap power supplies, if any are installed
b. Power supply cables on the system board
2. (Trained service technician only) Replace the system board.
System over recommended voltage on +2.5V
1. Reseat the following components:
a. Hot-swap power supplies, if any are installed
b. Power supply cables on the system board
2. (Trained service technician only) Replace the system board.
System over recommended voltage on
continuous +5V
1. Reseat the following components:
a. Hot-swap power supplies, if any are installed
b. Power supply cables on the system board
2. (Trained service technician only) Replace the system board.
Chapter 5. Diagnostics 223

Table of Contents

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the IBM x3200 M2 Type 4367 and is the answer not in the manual?

IBM x3200 M2 Type 4367 Specifications

General IconGeneral
ProcessorIntel Xeon 3000 Sequence, Intel Core 2 Duo, Intel Pentium Dual-Core
Memory Slots4 DIMM slots
ChipsetIntel 3200
Storage ControllerIntegrated SATA controller
Form FactorTower
MemoryUp to 8GB DDR2
StorageSATA
Hard Drive Bays4
RAID SupportRAID 0, 1
Network ControllerIntegrated Broadcom Gigabit Ethernet
Expansion Slots1 PCI-Express x8, 1 PCI-Express x1, 2 PCI
Power Supply400W fixed
Operating System SupportMicrosoft Windows Server, Red Hat Enterprise Linux, SUSE Linux Enterprise Server
Processor CoresDual-core, Quad-core (Xeon 3200 series)

Related product manuals