21
REMOTE CONTROL
Remote control (CI-V) information
D Command formats
• Manually entered position data
Command: 1A 05 0286, 0312, 0326,
23 02
1
: 0 ~ 9
~ 5
~ 9
0�1
~ 9
0�0
~ 9
0�00
~ 9
0 (Fixed)
0 (Fixed)
South latitude=0/North latitude=1
0 (Fixed)
100
: 0 ~ 1
10
: 0 ~ 9
1
: 0 ~ 9
~ 5
~ 9
0�1
~ 9
0�01
~ 9
0�00
~ 9
0 (Fixed)
0 (Fixed)
West longitude=0/East longitude=1
Latitude Longitude
10000 meter digit:
0 ~ 1
0 ~ 9
0 ~ 9
0 ~ 9
0 ~ 9
0�1
0 ~ 9
1
X X X X X X X 0 0 X 0 X X X X X X X X 0 0 X X X X X X X 0 X
2 3 4 5 6 7 8 9
:
X X X X
∙∙∙∙∙∙∙
X X X X
∙∙∙∙∙∙∙
X X
∙∙∙∙∙∙∙
X X
1 ~ 5: Latitude (dd°mm�mmm format)
6 ~ : Longitude (ddd°mm�mmm format)
~ : Altitude (0�1 meter steps)
* When reading the contents with no altitude, sends
, , , and as “FF�”
* When sending the contents with no altitude, set ,
, , and to “FF�”
• D-PRS Symbol setting
Command: 1A 05 0291 ~ 1A 05 0294,
1A 05 0310, 0324, 0335
XX X X
•
character�
• See “Codes for character entries” for the second
digit character� (p� 18)
• Alarm area (Group) setting
Command: 1A 05 0346
XX X X 0
X
digit: 0 ~ 5
digit: 0 ~ 9
digit: 0 ~ 9
digit: 0 ~ 9
digit: 0 ~ 9
• Data mode with filter width settings
Command: 1A 06
X X X X
01=FIL1
02=FIL2
03=FIL3
00=Data mode OFF*
01=Data mode ON
*
When 00 is set, also set 00 to 2
• Repeater tone/tone squelch frequency settings
Command: 1B 00, 1B 01
~ 2
~ 9
~ 9
~ 9
Fixed digit: 0*
Fixed digit: 0*
1*
00 X X X
X
*Not necessary when setting a frequency�
• DTCS code and polarity setting
Command: 1B 02
0 (fixed)
First digit: 0 ~ 7
Second digit: 0 ~ 7
Third digit: 0 ~ 7
Receive polarity: 0=Normal
1=Reverse
Transmit polarity: 0=Normal
XX 0 X X