105
Trouble Shooting Guide
PROBLEM DISPLAY LIGHTS
ON
SOLUTION
Gate stopped mid
-
travel
Stopped mid-travel
Entrapment stop
Obstruction detected
UL reset to clear
P1
CAN1
(red)
A1 (red)
I3
UL Entrapment activated. Check for
obstructions in operator and around
barrier. Push red UL rest button.
Check inherent settings.
Gate stops and reveres and stops
during closing cycle
Stopped mid-travel P1
CAN1
I3
Position Feedback Potentiometer has
failed, loose wire connections, or
improper wire connections.
Gate stops and reveres and stops
during opening cycle
Stopped mid-travel P1
CAN1
I3
Position Feedback Potentiometer has
failed, loose wire connections, or
improper wire connections.
Gate runs slow in both open and
close cycle.
Bad Position Pot Check potentiometer, turns with drive
sprocket, loose or broken wire.