104
Trouble Shooting Guide
PROBLEM DISPLAY LIGHTS
ON
SOLUTION
Gate opened and will not close Full Open
Pending Auto Close
P1
CAN1
I3
I5
Aux timer is active. Clear input to I5
Aux timer.
Gate opened and will not close Full Open
Pending Auto Close
P1
CAN1
I3
I6
Timer hold is active. Clear input to I6
Timer hold.
Gate opened and will not close Full Open
Pending Auto Close
P1
CAN1
I3
I7
Timer set is active. Clear input to I7
Timer set
Gate opened and will not close Full Open
Pending Auto Close
P1
CAN1
I3
I8
Reveres open loop is active. Clear
input to I8 Reveres open loop.
Gate opened and will not close Full Open
Pending Auto Close
P1
CAN1
I3
I9
Aux # 1 input is active. Clear input to
I9 Aux # 1 input.
Gate opened and will not close Full Open
Pending Auto Close
P1
CAN1
I3
I10
Aux # 2 input is active. Clear input to
I10 Aux # 2 input.
Gate opened and will not close Full Open
Schedule Auto-Open
P1
CAN1
I3
Auto-Open Schedule active. Turn
Auto-Open Schedule off in menu.
Gate opened and will not close Full Open
Low Voltage Failsafe
P1
CAN1
I3
Battery voltage is low. Check battery
charge for proper operation and
battery connections.
Gate in any position and will
not move
CAN1 Fuse F1 5 amp blown on Logic Board.
Replace with same type and rating.