prox.pad Plus IR Access System Installer Guide
Action Desired Press Details
Change Platform Parameters 32 # parameter # value # ** See Chart Below
Parameter Value
0 – Error Lockout Threshold 1 – 50 Attempts (Default = 3)
1 – Error Lockout Duration 1 – 255 Sec. (Default = 10 Sec.)
3 – Extended User Unlock Time 1 – 255 Sec. (Default = 10 Sec.)
4 – Facility Code (For commands 51 & 57) 0 – 255 (Default = 11)
8 – Anti-Passback Delay 2 – 240 (¼ sec increments; Default = 4, 1
sec)
Reset System Defaults Only 40 # 00000 # 00000 # ** Does not delete users
Set System Time 41 # hhmm # 0 # **
hhmm=hour/minute (24 Hour
Format)
Set System Date 42 # mmddyy # dow # **
mmddyy=month, date, year;
dow=day of week, 1=Sunday
Set Propped Door Time 44 # time # 0 # **
Time = 10-990 seconds;
(default=30 secs)
Set Forced Door Time 45 # time # 0 # **
Time =forced door time, to nearest
10’s seconds, entered as 30-990;
(default=10 secs)
Delete Entire Memory and Reset
System Defaults
46 # 00000 # 00000 # ** Deletes all memory including users
Program User – Code Only
50 # user type # user location #
code *repeat code *
User Types:
0 – Toggle
1 – Standard
3 – Lockout
4 – Extended
5 – Single Use
6 – Relock
7 – Emergency
8 – Communications Unlock
Program User – Code AND Card
By Presenting Card
50 # user type # user location #
code * repeat code ** <present
card>
User Types:
0 – Toggle
1 – Standard
3 – Lockout
4 – Extended
5 – Single Use
6 – Relock
7 – Emergency
8 – Communications Unlock