prox.pad Plus IR Access System Installer Guide
prox.pad Plus IR Default Settings
The table below lists the default settings for the prox.pad Plus IR unit as shipped from the factory. Subsequent sections in this chapter
explain how to change these default settings or program additional functions.
Table 3: prox.pad Plus IR Default Settings
Option Default Setting Option Default Setting
Master Code 1234 Lock Output Time 5 Seconds
Audio Keypress Feedback Enabled Visual Keypress Feedback Enabled
Auxiliary Relay Alarm Shunt Auto-Entry Disabled
Card/PIN Program Mode Disabled User Lockout Enabled
Internal REX Switch Disabled Timezones Disabled
Auto-Unlock Disabled First-In Auto-Unlock Disabled
DST Time/Date Format US Daylight Saving Time Enabled
Anti-Passback Enabled Anti-Passback Timer 1 second
Audio Alert 1 Forced Door Audio Alert Audio Alert 2 Propped Door Audio Alert
Forced Door Time 10 Seconds Propped Door Time 30 Seconds
Invalid PIN Lockout Count 3 Attempts Invalid PIN Lockout Time 10 Seconds
Extended Unlock Time 10 Seconds 26-Bit Facility Code 11
Daylight Saving Time
The prox.pad Plus IR supports the following Daylight Saving Time formats:
United States (US):
Begins: Second Sunday in March at 2:00 AM
Ends: First Sunday in November at 2:00 AM
European (EU):
Begins: Last Sunday in March at 2:00 AM
Ends: Last Sunday in October at 2:00 AM
Document # 6105681, Rev 1.1, D2a Page 7 of 32