EN
5 - ADJUSTMENTS AND SETUP VIP80E-II
5 - Pag. 2 / 8
5.1 PRELIMINARY NOTE ON ADJUSTMENT
INFORMATION:
before carrying out any adjustment, activate all safety devices provided and
check if it is necessary to inform the operators using the machine and people
working close to the area. In particular, it is recommended to adequately signal
the adjacent areas and to prevent anyone from approaching any of the devices
that, if activated, could cause unexpected dangerous situations and injure
people.
5.2 Pressure switch – Minimum threshold adjustment
After unscrewing the glass protection, the pressure
switch can be adjusted by turning the relevant
adjusting screw (A). Proper setting is 4.5 bar (0.45
MPa).
WARNING – CAUTION:
Do not further turn counterclockwise
when the green pointer is on 0, as this
may cause damage to the pressure
switch.
8070_05_01_1
A