TRADUCTION OF THE ORIGINAL INSTRUCTIONS FOR USE
BS 400/60 AFI-Eing ED.2011 rev.00 21/60
ER0023 broken band
ER0024 FREE
ER0025 blocked inverter (motor under stress?)
ER0026 too high motor absorption
ER0027 not correct position of the tool for starting the cutting cycle (blade locked in the workpiece?)
ER0028 vice pressure problem (vice too open/oil pressure?)
ER0029 blade unblocking -for SIRIO models only-
ER0030 bar end - in automatic cycle - (end of the material?)
ER0031 carriage not in correct position - for starting the automatic cycle -
ER0032 feeder vice (vice too open/closed?)
ER0033 piece counter selection on 0 (for automatic cycle)
ER0034 OIL PUMP DEACTIVATED - for hydraulic models - or DISCONNECTED AIR - for hydropneumatic models
ER9999 overflow in the machine timer (it is necessary to switch the system off and then on).
Remove the causes of the anomaly and push any other key to cancel the display code.
15.3.3. - SPECIAL FUNCTIONS of the key MODE (for qualified technicians or assistance staff only)
If you keep pushed the button MODE (10) for more than 3 seconds, you can enter a diagnostics menu used
for the technical assistance.
In this function all LED lights corresponding to the key MODE are on.
If you want to get out from this situation you have to push again the button MODE for 3 seconds.
The parameters consultation is always made by pushing for an instant the button MODE; the display shows:
P1 - historical piece counter of the machine
P2 - hour counter of the band motor functioning
15.3.4. - SPECIAL FUNCTIONS of the key TEST (for qualified technicians or assistance staff only)
If you push the key TEST (10) together with the button COOLANT ON (23) you can enter a menu used by the
technical assistance (the display shows: IN, DAC, .., and so on in case you push any bottons).
If you want to get out you can switch the machine off and then on, or you can push again TEST +
COOLANT ON.