Model 699A07
PORTABLE VIBRATION CALIBRATOR
Installation and Operating Manual
For assistance with the operation of this product,
contact the PCB Piezotronics, Inc.
Toll-free: 800-959-4464
24-hour SensorLine: 716-684-0001
Fax: 716-684-3823
E-mail: imi@pcb.com
Web: www.imi-sensors.com
Question and Answer IconNeed help?

Do you have a question about the IMI SENSORS 699A07 and is the answer not in the manual?

IMI SENSORS 699A07 Specifications

General IconGeneral
OutputVoltage
Case MaterialStainless Steel
Temperature Range-65 to +250 °F (-54 to +121 °C)
Sensing ElementCeramic
SealingHermetic

Summary

Portable Vibration Calibrator Installation and Operating Manual

Service, Repair, and Return Policies and Instructions

Model 699A07 User Manual

Introduction

699A07 Operation Guide

Basic Operation

Step-by-step guide for fundamental operation of the 699A07, including test setup.

Report Generation Workbook

Details on using the provided Excel workbook for creating calibration certificates.

Calibration Route

Information on creating and executing semi-automated tests using the Calibration Route firmware.

Test Setup

Detailed steps for setting up the 699A07 for testing, including sensor mounting and connections.

Selecting Input Mode

How to select input modes like ICP®, Voltage, or Modulated Current for different sensor types.

Setting the Frequency and Amplitude Units

Guide to setting desired frequency and amplitude units for calibration tests.

Transfer Records to USB Flash Drive

How to copy or move calibration records from the unit's memory to a USB flash drive.

Report Generation Workbook

Additional Features

Test Settings Menu

Configuring various test parameters like Cal Route, Source, Frequency Unit, Sensor Type, and Readout.

Theory of Operation

Recommended Practices

Operational Verification and Recalibration

Importance of periodic verification using a dedicated accelerometer and recalibration procedures.

Standard Checks for Transducers

Periodic checks for linearity and frequency response to validate transducer functionality.

Typical Accelerometer & Velocity Sensor Checkout

How to test accelerometers and velocity sensors by measuring frequency response.

Calibrating Charge-Mode Accelerometers

Procedure for testing charge-mode accelerometers using a charge amplifier and the 699A07.

Non-Contact Displacement Sensor Calibration

How to check accuracy, linearity, and frequency response of non-contact displacement sensors.

Non-Contact Displacement Sensor Test Setup

Detailed setup instructions for testing non-contact displacement sensors.

Proximity Probe Dynamic Linearity Calibration & Confirmation of Vibration Alarms

Calibrating proximity probes and confirming vibration alarm settings.

Creating a Proximity Probe Curve in Mils

Step-by-step guide to create a proximity probe calibration curve using mils.

Maintenance