33
12.3 ANTIGL (anti-freeze level).
Allows to set the room temperature for activation of the
anti-freeze function. Can be regulated from 0°C to 10°C
and is set at 5°C as standard.
12.4 ZONA (function not present on this model).
12.5 MANUTZ (programmed maintenance).
Sets the period for periodic maintenance (can be set from 6
to 24 months or “O ”). When the period has been set, the
telephone number that the user must contact to perform
periodic maintenance is set.
12.6
Association procedure in RF
.
To carry out an association in radio frequency between the
CAR
V2
and the relative Base, follow that reported below:
1) Access the protected menu of the CAR
V2
for RF
management (radio frequency): CODE via code “9977”;
2) e Test-RF menu will appear (RF>CHK);
3) By pressing the OK button, the RF>INS association/
installation menu will appear (if they are not already
associated, otherwise the RF>REM disassociation menu
will appear);
4) Within 30 seconds, activate the association stand-by
function on the Base by pressing the “test” button for at
least 4 seconds until the le LED on the base ashes;
5) Press the OK button on the CAR
V2
to launch the
association request;
6) If the procedure should fail, RF>INS will appear on
the CAR
V2
once again, otherwise, if the procedure is
successful, RF>REM will appear and one or more signals
will appear on the Base every 2 s;
7) At the end of the association procedure, wait at least 1
minute before regulating for communication between the
Base of the CAR
V2
and the boiler to be established.
12.7 RF disassociation procedure.
To carry out a disassociation in radio frequency between
the CAR
V2
and the relative Base, follow that reported below:
1) Access the protected menu of the
CAR
V2
for RF management
(radio frequency): CODE via code “9977”;
2) e Test-RF menu will appear (RF>CHK);
3) By pressing the OK button, the RF>REM disassociation/
removal menu will appear (if they are associated,
otherwise the RF>INS association menu will appear);