34
INSTALLER
USER
MAINTENANCE TECHNICIAN
TECHNICAL DATA
Error
Code
Anomaly signalled Cause Boiler status / Solution
31
Loss of remote control
communication
is occurs 1 minute aer communication loss between the boiler
and the remote control.
Switch the boiler on and o again (1).
37
Low power supply
voltage
is occurs when the power supply voltage is lower than the
allowed limits for the correct boiler operation.
If normal conditions are restored the boiler
restarts without having to be reset (1).
38 Loss of ame signal
is occurs when the boiler is ignited correctly and the burner
ame switches o unexpectedly; a new attempt at ignition is
performed and if normal conditions are restored, the boiler does
not have to be reset.
(1).
43
Block due to loss of
continuous ame
signal
is occurs if the “Flame signal loss” error occurs 6 times con-
secutively in 8.5 minutes.
Press the Reset button (1).
(1) If the block or anomaly persists, contact an authorised company (e.g. Authorised Technical Aer-Sales Service).
2.6 Information Menu.
Pressing the buttons (3 and 4) for 5 seconds, the “Information
menu” is activated, which allows to display some boiler func-
tioning parameters.
To scroll through the various parameters, press (3 and 4), to exit
from the menu press buttons (3 and 4) again for 5 seconds or press
button (2) for 5 seconds or wait for 60 seconds.
Id Parametro Descrizione
d1 Displays the ame signal (uA)
d2 Displays the primary exchanger output instant heating ow temperature
d3 Displays the instant output temperature from the DHW exchanger
d4 Displays the temperature set for the central heating set (if remote control is present)
d5 Displays the temperature set for the DHW set (if remote control is present)
d6
Displays the external environment temperature (if external probe is present).
If the temperature is below zero, the value is displayed ashing.

Table of Contents