3.29 TECHNICAL PARAMETERS FOR MIXED BOILERS IN COMPLIANCE WITH REGULATION 813/2013.
e yields in the following tables refer to the higher heating value.
Model/s: Victrix Pro 80 2ErP
Condensing Boilers: SI
Low temperature boiler: NO
Boiler type B1: NO
Co-generation appliance for central heating: NO Fitted with supplementary heating system: NO
Mixed heating appliance: SI
Element Symbol Value Unit Element Symbol Value Unit
Nominal heat output P
n
73 kW
Seasonal energy eciency of central
heating
η
s
91 %
For central heating only and mixed boilers: useful heat output For central heating only and mixed boilers: useful eciency
At nominal heat output in high tempera-
ture mode (*)
P
4
73.0 kW
At nominal heat output in high tempera-
ture mode (*)
η
4
87.5 %
At 30% of nominal heat output in a low
temperature mode (**)
P
1
21.9 kW
At 30% of nominal heat output in a low
temperature mode (**)
η
1
96.0 %
Auxiliary electricity consumption Other items
At full load el
max
0.119 kW Heat loss in standby P
stby
0.143 kW
At partial load el
min
0.024 kW Ignition burner energy consumption P
ign
0.000 kW
In standby mode P
SB
0.004 kW Emissions of nitrogen oxides NO
X
22
mg /
kWh
For mixed central heating appliances
Stated load prole Domestic hot water production eciency η
WH
%
Daily electrical power consumption Q
elec
kWh Daily gas consumption Q
fuel
kWh
Contact information IMMERGAS S.p.A. VIA CISA LIGURE, 95 - 42041 BRESCELLO (RE) ITALY
(*) High temperature mode means 60°C on return and 80°C on ow.
(**) Low temperature mode for condensation Boilers means 30°C , for low temperature boilers 37°C and for other appliances 50°C of return temper-
ature.
Model/s: Victrix Pro 100 2ErP
Condensing Boilers: SI
Low temperature boiler: NO
Boiler type B1: NO
Co-generation appliance for central heating: NO Fitted with supplementary heating system: NO
Mixed heating appliance: SI
Element Symbol Value Unit Element Symbol Value Unit
Nominal heat output P
n
90 kW
Seasonal energy eciency of central
heating
η
s
92 %
For central heating only and mixed boilers: useful heat output For central heating only and mixed boilers: useful eciency
At nominal heat output in high tempera-
ture mode (*)
P
4
90.0 kW
At nominal heat output in high tempera-
ture mode (*)
η
4
88.0 %
At 30% of nominal heat output in a low
temperature mode (**)
P
1
27.0 kW
At 30% of nominal heat output in a low
temperature mode (**)
η
1
96.8 %
Auxiliary electricity consumption Other items
At full load el
max
0.143 kW Heat loss in standby P
stby
0.145 kW
At partial load el
min
0.017 kW Ignition burner energy consumption P
ign
0.000 kW
In standby mode P
SB
0.005 kW Emissions of nitrogen oxides NO
X
18
mg /
kWh
For mixed central heating appliances
Stated load prole Domestic hot water production eciency η
WH
%
Daily electrical power consumption Q
elec
kWh Daily gas consumption Q
fuel
kWh
Contact information IMMERGAS S.p.A. VIA CISA LIGURE, 95 - 42041 BRESCELLO (RE) ITALY
(*) High temperature mode means 60°C on return and 80°C on ow.
(**) Low temperature mode for condensation Boilers means 30°C , for low temperature boilers 37°C and for other appliances 50°C of return temper-
ature.