INSTALLERUSER
MAINTENANCE TECHNICIAN
49
Victrix Tera 28 1
Id
Parameter
Parameter Description Range Default
Cus-
tomised
value
S0
DHW minimum no. of
fan revs
Denes the operating speed of the fan at minimum DHW
output
20 - 60
(x 50 =RPM)
27 (G20)
26 (G31)
S1
DHW maximum no.
of fan revs
Denes the operating speed of the fan at maximum DHW
output
S0 - 140
(x 50 =RPM)
121 (G20)
115 (G31)
S2
Fan speed
Ignition phase
Denes the operating speed of the fan during the ignition phase
40 - 80
(x 50 =RPM)
56 (G20)
56 (G31)
Victrix Tera 32 1
Id
Parameter
Parameter Description Range Default
Cus-
tomised
value
S0
DHW minimum no.
of fan revs
Denes the operating speed of the fan at minimum DHW
output
20 - 60
(x 50 =RPM)
28 (G20)
28 (G31)
S1
DHW maximum no.
of fan revs
Denes the operating speed of the fan at maximum DHW
output
S0 - 140
(x 50 =RPM)
128 (G20)
121 (G31)
S2
Fan speed
Ignition phase
Denes the operating speed of the fan during the ignition phase
40 - 80
(x 50 =RPM)
56 (G20)
56 (G31)
Victrix Tera 38 1
Id
Parameter
Parameter Description Range Default
Cus-
tomised
value
S0
DHW minimum no.
of fan revs
Denes the operating speed of the fan at minimum DHW
output
20 - 60
(x 50 =RPM)
27 (G20)
28 (G31)
S1
DHW maximum no.
of fan revs
Denes the operating speed of the fan at maximum DHW
output
S0 - 140
(x 50 =RPM)
122 (G20)
122 (G31)
S2
Fan speed
Ignition phase
Denes the operating speed of the fan during the ignition phase
40 - 80
(x 50 =RPM)
56 (G20)
56 (G31)