EasyManua.ls Logo

Immergas Victrix Tera 38 1 - Page 49

Immergas Victrix Tera 38 1
68 pages
Print Icon
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
INSTALLERUSER
MAINTENANCE TECHNICIAN
49
Victrix Tera 28 1
Id
Parameter
Parameter Description Range Default
Cus-
tomised
value
S0
DHW minimum no. of
fan revs
Denes the operating speed of the fan at minimum DHW
output
20 - 60
(x 50 =RPM)
27 (G20)
26 (G31)
S1
DHW maximum no.
of fan revs
Denes the operating speed of the fan at maximum DHW
output
S0 - 140
(x 50 =RPM)
121 (G20)
115 (G31)
S2
Fan speed
Ignition phase
Denes the operating speed of the fan during the ignition phase
40 - 80
(x 50 =RPM)
56 (G20)
56 (G31)
Victrix Tera 32 1
Id
Parameter
Parameter Description Range Default
Cus-
tomised
value
S0
DHW minimum no.
of fan revs
Denes the operating speed of the fan at minimum DHW
output
20 - 60
(x 50 =RPM)
28 (G20)
28 (G31)
S1
DHW maximum no.
of fan revs
Denes the operating speed of the fan at maximum DHW
output
S0 - 140
(x 50 =RPM)
128 (G20)
121 (G31)
S2
Fan speed
Ignition phase
Denes the operating speed of the fan during the ignition phase
40 - 80
(x 50 =RPM)
56 (G20)
56 (G31)
Victrix Tera 38 1
Id
Parameter
Parameter Description Range Default
Cus-
tomised
value
S0
DHW minimum no.
of fan revs
Denes the operating speed of the fan at minimum DHW
output
20 - 60
(x 50 =RPM)
27 (G20)
28 (G31)
S1
DHW maximum no.
of fan revs
Denes the operating speed of the fan at maximum DHW
output
S0 - 140
(x 50 =RPM)
122 (G20)
122 (G31)
S2
Fan speed
Ignition phase
Denes the operating speed of the fan during the ignition phase
40 - 80
(x 50 =RPM)
56 (G20)
56 (G31)

Table of Contents