EasyManua.ls Logo

Immergas Zeus Superior - Page 39

Immergas Zeus Superior
52 pages
Print Icon
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
37
STZSkW ed 12/07 ZEUS Superior kW
Technical Documentation
Technical Documentation
M5 Menu (CONFIG)
(an access code must be introduced)
1st Level 2nd Level Options Description Default value
Value set by
the technician
SERVICE
(BOIL.PAR.)
P67
(PUMP
MODE)
P67.1
(CONTI-
NUE)
In winter mode the pump is always powered and therefore always
operates
P67.2
P67.2
(INTERMIT)
In winter mode the pump is managed by the room thermostat or by
remote control.
P67.3
(ECO-
NOMY)
In winter mode the pump is managed by the room thermostat or by
remote control and by the boiler ow probe.
P68
(RT DALAY)
0s ÷ 500s
e boiler is set to ignite the boiler immediately after a room heating
request. In the case of particular systems (e.g. zone-based systems with
motorised valves etc.) it could be necessary to delay ignition.
0 seconds
P69
(ANTICYC)
0s ÷ 255s
e boiler has an electronic timer that prevents frequent ignition of the
burner in the heating phase.
180 seconds
P70
(CH RAMP)
0s ÷ 840s
e boiler carries out an ignition ramp to arrive from minimum heat
output to nominal heat output.
840 seconds
(14 minutes)
P71
(DHW OFF)
P71.1
(OFF1)
e ignition of the boiler for heating domestic hot water occurs when
the water contained in the strorage tank falls by 3°C with respect to the
set temperature
P71.1
P71.2
(OFF2)
e ignition of the boiler for heating domestic hot water occurs when
the water contained in the strorage tank falls by 10°C with respect to
the set temperature.
P72
(FLOW REG)
AUTO
OFF
8 L/M
10 L/M
12 L/M
Independently from the options that can be displayed or set, this
parameter has no eect on boiler functioning.
FIXED ON
AUTO
RELE 1
(optional)
RELE1.OFF Relay 1 not used
RELE1.1
RELE1.1 In a system divided into zones, relay 1 controls the main zone.
RELE1.2
e relay signals the intervention of a boiler block (Can be combined
with an external signalling device, not supplied)
RELE1.3
e relay signals that the boiler is on
(Can be combined with an external signalling device, not supplied)
RELE1.4
Controls the opening of the external gas valve in concomitance with an
ignition request of the burner in the boiler.
RELE 2
(optional)
RELE2.OFF Relay 2 not used
RELE2.OFF
RELE2.6
Relay 2 activates the remote lling electrovalve (Optional)
e control can take place from CAR or Super CAR
RELE2.2
e relay signals the intervention of a boiler block Can be combined
with an external signalling device, not supplied)
RELE2.3
e relay signals that the boiler is on
(Abbinabile ad un segnalatore esterno non fornito)
RELE2.4
Controls the opening of the external gas valve in concomitance with an
ignition request of the burner in the boiler.
RELE2.5 In a system divided into zones, relay 2 controls the secondary zone
RELE 3
(optional)
RELE3.OFF Relay 3 not used
RELE3.OFF
RELE3.7
Controls the storage tank recirculation pump
(ricirculation pump optional)
RELE3.2
e relay signals the intervention of a boiler block (Can be combined
with an external signalling device, not supplied)
RELE3.3
e relay signals that the boiler is on
(Can be combined with an external signalling device, not supplied)
RELE3.4
Controls the opening of the external gas valve in concomitance with an
ignition request of the burner in the boiler.
P76
(EXT. T.
CORR)
-10°C ÷
+10°C
If the reading of the external probe is incorrect, it can be corrected to
compensate any environmental factors.
0°C

Related product manuals