IMO GmbH Gässlesweg 6 D-75334 Straubenhard t Tel.: 070 82 491 80 Fax: 604 36 www.imo-ag.com info@imo-ag.com
31
GmbH
9. Technical information
The water is heated in a through-flow heater; as a result there are no inconvenient heater
bars Inside the chamber. The water protection syste m and the bottom-pan ensure that leakage
of water is virtually impossible. This gives a high degree of protection agains water damage.
Very quit operation is achieved through comprehensi ve 6-sided sound insulation.
washing temperature 20°C - 70°C
washing time per washing process 5 - 40 min.
rinsing temperature 20°C - 70°C
rinsing time per rinsing process 2 - 20 min.
temperature / warm air drying 50°C - 100°C
(Due to heat losses through radiation and conduction the the chamber temperature
is approx. 80% of the slected drying temperature).
duration / extra drying 0 - 600 min.
(Wash-only and dry-only programs can be operated)
power supply 230V AC / 50Hz
power consumption 2,4kW
water consumption per filling approx. 5-6l deionised water
circuit board size (by using both spraying at the bottom max.: 405mm x 2 60 mm
levels as well as of both baskets) at the bottom max.: 405mm x 230 mm
circuit board size (by dismantled top spraying level
max.: 405mm x 5 55 mm
and by using bottom basket)
internal space dimensions H x W x D 5 6 x 49 x 48 cm
overall dimensions H x W x D 9 7 x 60 x 77 cm
weight
+/-2°C
+/-2°C
+/-5°C
approx. 80kg
Running noise (Cleaning) approx. 50 dB (A)
Running noise (drying) approx. 65 dB (A)