Do you have a question about the IMT Analytics FlowAnalyser PF-300 PRO and is the answer not in the manual?
Oxygen concentration range | 0 to 100% |
---|---|
Temperature range | 0 to 50°C |
Operating Temperature | 10 to 40°C |
Measurement Range | 0.1 to 300 L/min |
Pressure range | ±150 mbar |
Resolution | Flow: 0.01 l/min, Pressure: 0.01 mbar, Volume: 0.01 l, O2: 0.1% |
Response Time | <20 ms |
Power Supply | 100-240 V AC, 50/60 Hz |
Display | color touchscreen |
Outputs | USB |
Dimensions | 220 x 100 x 50 mm |
Covers document validity, software versions, naming conventions, cross-references, and version details.
Defines the product's intended use for medical device calibration and lists its measurement parameters.
Explains hazard symbols, personnel requirements, and manufacturer responsibility for safe operation.
Details manufacturer responsibility, warranty exclusions, and the device's specified service life.
Details instrument values like flow, pressure, and ventilation parameters with their ranges and accuracies.
Lists supported gas standards for converting flow and volume readings to standard conditions.
Details power supply requirements, battery operation time, charging, and care.
Lists compliance standards, approvals, and explains device labels and symbols.
Specifies the hardware and software requirements for connecting the device to a PC.
Details package contents, power connection, mechanical connectors, and flow channels.
Explains USB, RS-232, external trigger, and Ethernet ports for connectivity and control.
Covers powering the device on/off, the start screen, and using Direct Access Controls (DAC).
Details the various touch gestures for operating the multi-touch screen effectively.
Presents the main menu structure and how to access and configure device settings.
Explains numerical/graphical readings and the procedure for software updates.
Covers device applications, test reports, and setting the gas type and standards.
Describes the filter options available to average readings and reduce noise.
Instructions for performing zero calibration after the device has warmed up.
Explains the two methods for calibrating the oxygen cell: air only and air/100% oxygen.
Details the OR-703 components, capabilities, intended use, warnings, and limitations.
Explains the operational principle, connection procedure, and LED status indicators.
Details sensor calibration procedures and guidelines for servicing and care.
Lists the physical data, ambient conditions, accuracy, and rise times for the OR-703.
Explains the role of triggers in reading ventilation cycles and their importance for measurement accuracy.
Illustrates ventilator connection variants and details standard trigger values and base flow.
Guides on setting triggers, analyzing curves, and handling special measurement cases like Vti/Vte.
Emphasizes careful servicing, use of approved parts, and notes on component replacement.
Outlines regular routines for cleaning the device surface and checking the protection filter.
Provides contact details for customer service, technical support, and sensor recertification.
Lists the ordering address and details available spare parts with article numbers.
Details the operator's responsibility for disposing of the device and accessories according to regulations.
Provides a list of abbreviations and their definitions used in the manual.
Details various measurement parameters and their corresponding units of measurement.
An alphabetical index of topics covered in the manual with corresponding page numbers.